RGP-35 series horizontal rotary ac disconnector for 35 kV

The outdoor horizontal rotary AC disconnector of type RGP-35/1000 (2000) NF1 with drives of PR10, PR11, PR12, PR20, PR-K, PD and PDS series is designed for closing and opening electrically dead high-voltage electric circuit sections of 35 kV as well as for grounding deenergized sections by using stationary grounding blades, which will ensure safe operation at the deenergized section. Climatic category is UKhL (temperate and cold weather) according to GOST 15150 (NF according to IEC), placement category 1 according to GOST 15543.1 for disconnectors with protection rating IP00 according to GOST 14254-96.

RGP-35 series horizontal rotary ac disconnector for 35 kV

RGP-35 series disconnectors are manufactured in single-pole, two-pole and three-pole versions, in the form of separate poles or assembled on the frame.

RGP-35 series disconnectors are manufactured in the following versions:

  1. RGPZ-1a-35/1000(2000) NF1 with one grounding blade on the part of stationary column;
  2. RGPZ-1b-35/1000(2000) NF1 with one grounding blade on the part of rotating column;
  3. RGPZ-2-35/1000(2000) NF1 with two grounding blades;
  4. RGP-35/1000(2000) NF1 without grounding blades.

Engineering data:

Parameter name
Single-pole
Two-pole
Three-pole
Rated voltage, kV
35
Maximum operating voltage, kV
40.5
Rated current, Ir, A
1000(2000)
Rated short-time withstand current (short-time thermal current), IT, kA
20(35)
Rated short-time withstand current lead time (short-circuit time), sec:
- for the main blades
- for the grounding blades
 
 
3
1
The highest peak of the rated short-time current (short-time electrodynamic current), Id, kA
50(87)
Permissible mechanical load on the lead-outs from the wires connected taking into consideration the effect of wind loads (wind speed up to 15 m/s) and the formation of ice (rain crust thickness up to 10 mm), no less than, N
500(750)
The highest force applied to the drive, at operating arm’s length together with an extension of 1.5 m, no more than, N
245
Weight of the disconnector, no more than, kg
87(102)
207(301)
291(378)
Disconnector dimensions, no more than, mm
- length
- width
- height
 
485
810
810
 
1783
810
810
 
2874
810
810

The insulation of each pole consists of two insulators. Depending on the disconnector version, insulators of various degrees of insulation are used. Upon customer’s request, disconnectors can be supplied with other types of insulators.

They are manufactured based on the drawings and technology developed by the “Electroschield TM-Samara” Group of Companies.

Made in accordance with the Technical Specifications TSh 64-00212883-43:2012. The product has been certified by the National Certification System of the Republic of Uzbekistan and Certification System of the Russian Federation (GOST-R).

 

Warning: PHP Startup: Unable to load dynamic library '/usr/local/php-5.6.40/lib/php/20131226/http.so' - /usr/local/php-5.6.40/lib/php/20131226/http.so: cannot open shared object file: No such file or directory in Unknown on line 0