K-63 series indoor switchgears and controlgears for a voltage of 6(10) kV

K-63 series switchgears and controlgears are intended for the reception and distribution of three-phase AC electric power with a commercial frequency of 50 Hz and voltage of 6-10 kV.

K-63 series indoor switchgears and controlgears for a voltage of 6(10)

K-63 series switchgears and controlgears are used as 6(10) kV switchgears of different-purpose substations, including grid-connected substations, substations for industrial facilities, oil-field substations, substations for power supply to agricultural consumers, and railway transport substations.

K-63 series switchgears and controlgears are designed for indoor operation (climatic category is U3 according to GOST 15150-69 (N3 according to IEC)) under the following conditions:

  1. altitude above sea level: up to 1000 m;
  2. upper (effective) value of ambient temperature: no higher than +40º C; 
  3. lower value of ambient temperature: no lower than -25º C; 
  4. atmosphere type: II according to GOST 15150-69 (approximately similar to the atmosphere of industrial areas).

The construction of K-63 series switchgears and controlgears are earthquake-proof within the full range of earthquake effects up to 9 magnitudes on the MSK-64 scale, including at the level of 25 m according to GOST 17516.1.3-90.

K-63 series switchgears and controlgears can operate at an altitude above sea level above 1000 m; at that, one should follow the instructions of GOST 8024, GOST 1516.3, and GOST 14693.

K-63 series switchgear and controlgear cabinets comply with the requirements of GOST 14693. 

Parameter name
Value
Rated (linear) voltage, kV
6; 10
Maximum operating (linear) voltage of the cabinets, kV
7.2; 12
Rated current of the main circuits of the switchgear and controlgear cabinets, A
630; 1000; 1600
Rated current of busbars, A
1000; 1600; 2000; 2500; 3150
Rated breaking current of the circuit breaker embedded in the switchgear and controlgear cabinet, kA
12.5; 16; 20; 31.5
Short-time thermal current, kA
20; 31.5
Short-time thermal current lead time, sec.:
3
Rated short-time electrodynamic current of the main circuits, kA
51; 81
Rated frequency, Hz
50
Insulation type
Air; composite
Maintenance conditions
Bilateral maintenance
Overall dimensions, width x height x depth, mm:
750 x 2268 x 1165 (1365)
Weight, kg:
1000

Made in accordance with the Corporate Standard Ts 00212883-020:2014.

Attached documents:

  • Indoor switchgear & control gear of K-61 series technical description.

    type: pdf | size: 0 kB
    Indoor switchgear & control gear of K-61 series technical description with request forms.
    Download

 

Warning: PHP Startup: Unable to load dynamic library '/usr/local/php-5.6.40/lib/php/20131226/http.so' - /usr/local/php-5.6.40/lib/php/20131226/http.so: cannot open shared object file: No such file or directory in Unknown on line 0